Settings
Setting the operating parameters
1
Main view
2
Heater settings
3
Circulation pump settings
4
Settings display
5
Network
6
Systemsettings
7
Log
2
Pump
- This symbol shows the status of the circulation pump. It also acts as a switch. By tapping the symbol, the pump can be switched on and off manually.
3
Heating rod
- This symbol shows the status of the heating element. It also acts as a switch. By tapping the symbol, the heating element can be switched on and off manually.
4
Return temperature
- The instrument displays the current return temperature on the sensor.
5
Temperature target
- The set target temperature with the set “spread”.
6
Info Page
- Here you can access the "Info" page with links/QR codes to the control web interface and the documentation/data portal.
7
Main View
- This will always take you back to this main view.
8
Settings
- You can find the settings using this button - the individual setting areas are described below.
9
At the top right there are status symbols (without numbering)
- Displays WiFi network status and reception strength.
- Displays the connection status to the cloud.
1
Operating hours: The operating hours of the heating element. The average life expectancy of heating elements is around 20 years, but depends heavily on the water quality.
2
Heating element: When the heating element is switched on, the pump is automatically activated for safety reasons. When the heating element is switched off, the pump continues to run (pump overrun).
3
Target temperature: Target temperature of the water in the return
4
Spread: Allowed spread of water temperature. This affects the timing of the heating element.
5
ALARM: The temperature at which the alarm is triggered is set here. In the event of an alarm, the red socket is energized and a connected 230V signaling device (e.g. light or siren) is supplied with voltage. The alarm can be switched off on the device screen. However, if the error is not corrected within a certain period of time, the alarm will be triggered again.
1
Operating Hours: The operating hours of the pump. The average life expectancy of circulation pumps is approximately 20 years.
2
Pump: When the pump is switched off, the heating element is deactivated for safety reasons.
3
Interval: Pump interval in summer operation
4
Pump running time: The pump running time in interval operation.
2
Menu timeout: The time until the display automatically switches to the main view.
3
Screensaver: Activates the LCD screensaver without turning off the backlight (test function). Tap the screen to turn off.
4
LCD: Turns off the backlight. Tap the screen to turn on.
The network data is displayed here.
Currently only WiFi with DHCP is supported. Static IP and a wired Ethernet connection in future releases. The control can generally be retrofitted.
The system settings contain the following settings and data:
The internal log file is displayed here. For error analysis or support purposes, you may be able to find helpful information here. The different colors of the messages mean: